Dual Channel Vehicle Loop Detector 20-2000uh with 110-240VAC for Parking Barrier Gates

Place of Origin China
Brand Name JUTAI
Certification CE
Model Number LD-200
Document LD-200.202.pdf
Minimum Order Quantity 1
Price Negotiation
Packaging Details Cartoon
Delivery Time 5 - 8 working days
Payment Terms T/T,L/C,D/A,D/P,Western Union,Paypal,MoneyGram,Alipay
Supply Ability 1000 pieces per month
Product Details
Power Requirements 110-240VAC (48 To 63Hz) Self-Turning Range 20-2000uh
Sensitivity 16-Way Selectable/ Highest 0.010%Dl/L/Lowest 2.56% Operation Temp -40 ~ +70℃
Response Times Turn-on 10-90ms/Turn-off 10-90ms Specification 13.6*8.6*5.2
Highlight

20-2000uh Loop Detector

,

Dual Channel Vehicle Loop Detector

,

110-240VAC Inductive Loop Detector

Leave a Message
Product Description
LD-200 Loop Detector for Cars Trucks Motorcycles Barrier Gates and Industrial Door Applications
Product Overview

Double Coil Vehicle Loop Detector for vehicle counting detection and parking management. Advanced vehicle detection system for parking management and access control applications.

Key Advantages
  • Wide Sensing Range and High Sensitivity: Accurate detection of various vehicles with broad sensing range from 15 to 2000μH
  • Automatic Reset Function: Enhances system stability by automatically resetting in case of malfunction
  • Direction Recognition: Precise activation based on vehicle movement direction
  • 40000V Lightning Protection: Robust protection ensures long-term durability
  • Wide Operating Environment: Stable performance from -40°C to +70°C
Core Functionality
  • Vehicle Detection: Accurately detects vehicles using inductive sensing technology based on changes in inductance
  • Direction Recognition: Identifies specific vehicle movement directions for precise gate control
  • Automatic Reset: Eliminates manual intervention by automatically resetting during malfunctions
  • Relay Output: Provides relay output signals for gate control, traffic management, and vehicle counting
Applications
  • Traffic Management Systems
  • Gate Automation
  • Parking Facilities Management
  • Access Control Systems
  • Traffic Light Control
  • Vehicle Counting and Analysis
Product Images
Double Channel Car Parking Management Inductive Loop Detector
Double Channel Car Parking Management Inductive Loop Detector
Loop Detector Connection Diagram
Loop Detector Connection Diagram
Sensitivity Selection Switches
Sensitivity Selection Switches
Indicators and Switches
Indicator Status Meaning
Power LED (RED) Illuminates Power ON
CH1 Detecting LED Continuous Vehicle detection
Slow Blinking Loop short circuit or insufficient twists
Fast Blinking Loop open circuit or excessive twists
CH2 Detecting LED Continuous Vehicle detection
Slow Blinking Loop short circuit or insufficient twists
Fast Blinking Loop open circuit or excessive twists
Sensitivity Selection

Sensitivity and frequency adjustments using 7-way and 10-way dip switch settings:

  • Dip switches 6, 7, 8 control CH1 sensitivity (0.8 to 0.015)
  • Dip switches 3, 4, 5 control CH2 sensitivity (0.8 to 0.015)
Channel 1 Loop Function Selection
Channel 1 Loop Function Selection
Special Functions Setting
Special Functions Setting
CH1 and CH2 Sensitivity Selection
CH1 and CH2 Sensitivity Selection
Frequency Setting
Frequency Setting
Reset Button Note: The LD-200 must be reset every time a setting change is made to the Dip switches.
Installation Guidelines
  • Use ferromagnetic wires for induction coil (up to 500 meters total length)
  • Coil cutting size: Rectangle 1.0-2.0m length * 0.8-1.2m width
  • Avoid right angles at corners
  • Keep product plug and socket in vertical direction during installation
Recommended Coil Installation Overview
Recommended Coil Installation Overview
Proper Installation Orientation
Proper Installation Orientation
System Integration

JUTAI LD200/202 Double Channels Vehicle Loop Detector Series with direction recognition function for single-channel entry and exit applications.

Compatible Components
  • JUTAI One door controller (Model: AC-11)
  • JUTAI gate barrier (Model: BR-110)
  • JUTAI long-range RFID reader (Model: PUHF-9)
  • High-temperature resistance loop coils (Model: JTHT-11)
Operation Process
Entry Process
  1. Simultaneous Loop Coil Activation: Both loop coils are pressed when car enters
  2. UHF Reader Activation: LD-200/202 triggers UHF reader at entrance
  3. Card ID Reading: Reader transmits ID to controller via Wiegand output
  4. ID Verification and Gate Opening: Controller verifies ID and opens gate barrier
  5. Vehicle Entry: Barrier arm automatically lowers after vehicle passes
  6. Safety Assurance: LD-100/102 provides safety and anti-smashing functionality
Exit Process
  1. UHF Reader Activation: LD-200/202 triggers inside UHF reader
  2. ID Verification and Gate Opening: Controller verifies ID and opens exit barrier
  3. Vehicle Exit: Barrier arm lowers automatically after vehicle passes
  4. Safety Measures: LD-100/102 provides safety during exit process
Direction Recognition

Ensures double channels loop detector does not trigger signal again when car passes another UHF reader, maintaining accurate entry/exit records.

Direction Recognition Function
Direction Recognition Function
Independent Working Mode

The JUTAI LD-200/202 can function as two independent single-channel loop detectors for standard one-in and one-out parking lots:

  • One loop coil triggers reader and reads card
  • Other loop coil provides barrier anti-smashing function
  • Cost-saving benefit by reducing hardware requirements
Independent Working Mode Configuration
Independent Working Mode Configuration
Additional Product View
Additional Product View
Product Installation Example
Product Installation Example
System Application Diagram
System Application Diagram