Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure

Place of Origin China
Brand Name JUTAI
Certification CE
Model Number CL20-8L
Document CL05-8L User Manual.pdf
Minimum Order Quantity 1
Price Negotiation
Packaging Details Cartoon
Delivery Time 5 - 8 working days
Payment Terms T/T,L/C,D/A,D/P,Western Union,Paypal,,MoneyGram,Alipay
Supply Ability 1000 pieces per month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
IP Rating IP67 Function Blanking
Sensing Distance 8m Material Aluminum Alloy
Feature Corrosion Resistant Power Voltage DC12-24V
Operating Temperature -20~60℃ Operating Current <50mA
Output No/Nc, COM Working Current <20mA@DC12V-24V
Specification 2000*21*15 Mm
Highlight

Industrial door protection light grid

,

CE certified light curtain

,

IP67 enclosure light grid

Leave a Message
Product Description
 


Product Description


Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 0


Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure

The JUTAI CL20-8L Industrial Door Protection Light Grid is a CE-certified safety sensing solution designed exclusively for industrial door scenarios. It forms an 8-beam invisible protective grid between the emitter and receiver, instantly triggering safety responses (door reversal, stopping) when personnel, objects, or equipment intrude the detection area. With an IP67 waterproof/dustproof enclosure and rugged aluminum alloy construction, it delivers reliable anti-pinch and intrusion protection for industrial doors in harsh industrial environments, ensuring compliance with safety standards and operational continuity.

Core Specifications (Detailed Parameter Table)

Parameter Specification
Model CL20-8L
Certification CE certified (compliant with safety standards for industrial machinery)
Protection Rating IP67 (dustproof + waterproof)
Housing Material Aluminum alloy
Working Voltage DC12-24V
Working Current Transmitter: <65mA @DC12V; Receiver: <20mA @DC12V
Output Configuration NO/NC relay output (default NO, configurable to NC); COM terminal included
Operating Range (Emitter to Receiver) 1-8m
Maximum Protection Height 1729mm
Number of Photocells 8 beams
Cable Length Transmitter: 8m; Receiver: 4m
Connector Type Transmitter: 5-pole M8 male connector; Receiver: 5-pole M8 male connector
Operating Temperature -20°C ~ +60°C
Key Function Industrial door anti-pinch protection + Blanking Mode (anti-false alarm)
LED Status Indicators Transmitter: Steady blue (normal operation); Fast-flashing red (voltage <9V or >28V)

Receiver: Steady red (object/personnel blocked); Steady blue (no obstruction); Flashing blue (first power-on, emitter-receiver misalignment)
Installation Hole Dimensions (Unit: mm) 14, 29, 75, 80, 175, 19.7, 21.4, 259

Key Functions & Advantages (Clear, Detailed Points)

1. CE Certification & Safety Compliance

  • Meets international safety standards for industrial machinery, ensuring compliance with workplace safety regulations in global industrial settings.
  • Rigorously tested for reliability and safety, providing legal and practical protection for industrial door operations.

2. IP67 Enclosure for Harsh Environments

  • Fully dustproof and waterproof, withstanding temporary water immersion, heavy dust, and industrial contaminants—ideal for outdoor-installed industrial doors, dusty workshops, or humid environments.
  • Aluminum alloy enclosure resists mechanical wear, vibration, and corrosion, adapting to high-frequency industrial door operations and harsh working conditions.

3. Targeted Industrial Door Protection

  • 8-beam light grid covers the full height of industrial doors (1729mm), eliminating safety blind spots and accurately detecting hands, limbs, tools, or goods to prevent pinching/crushing accidents.
  • Instant response to beam interruption, matching the operational speed of industrial doors (fast doors, roller shutters) to avoid safety lags.

4. Blanking Mode for False Alarm Prevention

  • Specialized for industrial door gaps: Blocking the first channel of the light grid does not trigger safety responses, adapting to sequential beam blocking during normal door closure.
  • Avoids unnecessary operational interruptions while retaining full protection against unintended intrusions, balancing safety and efficiency.

5. Easy Installation & Intuitive Operation

  • Color-coded wiring simplifies connection to industrial door control systems, reducing installation errors (details in Wiring Guide).
  • Standardized installation holes enable flexible mounting on various industrial door frames, ensuring firm fixation and stable operation.
  • LED indicators provide real-time status feedback, allowing on-site personnel to quickly identify operational issues without professional tools.

Wiring Guide (Standardized Table with Notes)

Component Wire Color Function Detailed Notes
Transmitter Red DC12-24V Positive Power Supply Connect to a stable DC power supply; avoid overvoltage/undervoltage to prevent device damage
Transmitter Black Ground (GND) Connect to power supply negative terminal; ensure reliable grounding to avoid signal interference
Transmitter Green Reserve No connection required for basic use
Transmitter Yellow Reserve No connection required for basic use
Transmitter White Reserve No connection required for basic use
Receiver Red DC12-24V Positive Power Supply Use the same power source as the transmitter for consistent voltage
Receiver Black Ground (GND) Shared ground with the transmitter to ensure signal stability
Receiver Green NO/NC Output (Default NO) Connect to the industrial door control system’s safety signal input terminal
Receiver Yellow Configurable NC Switches to NC output after Blanking Mode activation (matches door control system requirements)
Receiver White COM (Common Terminal) Must be connected to the door control system’s corresponding terminal for normal output function

Critical Warnings

  • Do NOT connect NO/NC terminals (Green/Yellow wires of the receiver) to the power supply positive terminal—this will permanently damage the optical relay.
  • Keep connecting cables away from high-voltage/high-current conductors to avoid signal interference or cable damage.

Blanking Mode Activation Steps (Step-by-Step)

  1. Complete wiring according to the Wiring Guide and confirm no connection errors.
  2. Power on the light grid (ensure the power supply meets DC12-24V requirements).
  3. Within 1 minute of power-on, touch the receiver’s Green wire (NO output) to its Black wire (GND) five consecutive times.
  4. Observe the receiver’s Red light blinking—this indicates successful activation: The Yellow wire switches to NC mode, and Blanking Mode is enabled.
  5. Test the function: Normal door closure (blocking the first channel) will not trigger safety responses; intrusion of personnel/objects will trigger immediate door reversal/stopping.

Application Scenarios (Targeted, Detailed List)

  • Industrial Fast Doors: High-speed roll-up doors in factories, logistics centers, and production lines.
  • Roller Shutter Doors: Industrial roller shutters in warehouses, workshops, and loading docks.
  • Sectional Industrial Doors: Large industrial doors in factories, storage facilities, and industrial parks.
  • Special Environment Industrial Doors: Cold storage industrial doors, outdoor industrial doors, and dusty workshop doors (resistant to temperature extremes, dust, and moisture).

Troubleshooting (Comprehensive Problem-Solution Table)

Fault Symptoms Possible Causes Detailed Solutions
Receiver’s blue light flashes continuously after power-on Emitter and receiver misalignment (light beams not paired) 1. Adjust the mounting positions to ensure both devices are parallel. 2. Remove obstacles blocking the light path between emitter and receiver. 3. Tighten mounting screws to avoid vibration-induced misalignment.
Transmitter’s red light flashes fast Power supply voltage <9V or >28V 1. Use a multimeter to test the power supply voltage. 2. Replace with a stable DC12-24V power supply. 3. Check for voltage drops caused by long cables and replace with thicker cables if necessary.
Light grid works normally (LED indicators correct), but door has no anti-pinch action Wiring error (incorrect connection of NO/NC or COM terminal) 1. Recheck wiring against the guide—ensure Green/Yellow (output) and White (COM) terminals are connected to the door control system’s safety interface. 2. Verify the door control system is set to “external safety sensor input” mode.
Unable to enter Blanking Mode 1. Operation exceeds 1-minute window after power-on 2. Light leakage during door descent 3. Bottommost beam blocked by debris 4. Door/obstruction fails to meet minimum continuous blocking distance 1. Power off and restart, then activate within 1 minute. 2. Fix door sealing to prevent light leakage. 3. Clear debris blocking the bottommost beam. 4. Adjust the door or obstruction to meet the continuous blocking distance requirement.

Installation Guidelines (Detailed, Operable Steps)

  1. Pre-Installation Preparation:
    • Confirm the industrial door’s opening height and width—ensure the light grid’s protection height (1729mm) and operating range (1-8m) match.
    • Prepare a stable DC12-24V power supply and check the device for intact components (no damaged cables or connectors).
  2. Mounting Operation:
    • Install the emitter and receiver vertically on both sides of the industrial door frame, ensuring the light grid covers the full door opening without blind spots.
    • Align the device’s installation holes with the door frame, fix with matching screws (ensure firm installation to resist door vibration).
    • Route the 8m (transmitter) and 4m (receiver) cables along the door frame, avoiding sharp edges or high-pressure areas.
  3. Wiring & Debugging:
    • Follow the Wiring Guide to connect power, ground, and signal cables—double-check to avoid positive/negative reversal or incorrect output terminal connections.
    • Power on the device: Confirm the transmitter’s steady blue light and receiver’s steady blue light (normal power-on).
    • Align the light grid: If the receiver’s blue light flashes, adjust the emitter/receiver positions until the light stabilizes.
    • Activate Blanking Mode as instructed and test the anti-pinch function to ensure normal operation.

Usage & Maintenance Caveats (Detailed Reminders)

  • Cable Protection: Keep cables away from high-voltage conductors, door machinery, and forklift paths to avoid extrusion, damage, or interference.
  • Lens Maintenance: Regularly wipe the emitter/receiver lenses with a dry, soft cloth to remove dust, oil stains, or condensation—dirty lenses will affect detection accuracy.
  • Physical Protection: Do not bend, twist, or drop the device; avoid scratching the aluminum alloy housing or infrared lenses.
  • Light Source Avoidance: Prevent direct sunlight or other infrared light sources from shining on the receiver to avoid false triggers.
  • Blanking Mode Usage: Ensure the door or obstruction used for Blanking Mode meets the minimum continuous blocking distance requirement.
  • Regular Inspection: Periodically test the anti-pinch and Blanking Mode functions; check wiring tightness and connector integrity to ensure long-term reliability.
For technical support, customization, or bulk inquiries, visit our official website: https://www.accesssecuritysolution.com/

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 1


 

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 2


Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 3

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 4

Customer Success Stories

1. Cold Storage Giant: Reliable Operation at -25°C
"JUTAI’s sensor eliminated downtime in our cold storage facility. The IP67 rating ensured reliable operation even at -25°C."
— Michael Chen, Warehouse Manager, Leading Cold Chain Logistics Provider
 
2. Automotive Manufacturing Leader: Seamless Integration
"The dual - mode feature allowed seamless integration into our existing infrastructure. Installation was effortless!"
— Lisa Wang, Safety Engineer, Global Automotive Manufacturer
 
3. Pharmaceutical Plant: Compliance & Efficiency
"JUTAI’s CE - certified sensor met our safety standards while reducing maintenance costs by 30%."
— David Li, Plant Director, International Pharmaceutical Corporation
 
4. E - commerce Warehouse: Accident - Free Operations
"After installing JUTAI’s 16 - beam sensor, we saw a 100% reduction in conveyor - related incidents."
— Sarah Zhang, Safety Officer, Top E - commerce Fulfillment Center
 
5. Heavy Machinery Manufacturer: Enhanced Operator Safety
"The sensor’s rapid response time (<=20ms) protected workers from robotic arm collisions during high - speed operations."
— John Wu, Engineering Manager, Industrial Equipment Producer
 
6. Food Processing Plant: Hygienic & Durable
"The IP67 aluminum housing resists water in our food processing lines while maintaining accuracy."
— Emily Chen, Quality Assurance Manager, Global Food & Beverage Company
 
7. Automated Warehouse: AGV Navigation Safety
"JUTAI’s sensor improved AGV collision avoidance, reducing downtime by 25%."
— Kevin Liu, Logistics Director, Automated Storage Solutions Provider
 
8. Fire & Safety Provider: Fire Door Compliance
"The sensor ensures fire doors close safely without compromising personnel safety during drills."
— Jason Zhou, Technical Lead, Fire Protection Systems Company





Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 5

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 6

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 7

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 8

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 9

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 10

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 11

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 12

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 13

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 14
Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 15
Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 16

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 17

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 18
Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 19

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 20

Industrial Door Protection Light Grid with CE Certification & IP67 Enclosure 21