Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection

Place of Origin China
Brand Name JUTAI
Certification CE
Model Number LD-202
Document LD-200.202.pdf
Minimum Order Quantity 1
Price Negotiation
Packaging Details Carton
Delivery Time 5 - 8 working days
Payment Terms T/T,L/C,D/A,D/P,Western Union,Paypal,,MoneyGram,Alipay
Supply Ability 1000 pieces per month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Power Requirements 12-24V Self-Turning Range 20-2000uh
Sensitivity 16-Way Selectable/ Highest 0.010%Dl/L/Lowest 2.56% Operation Temp -40 ~ +70℃
Response Times Turn-on 10-90ms/Turn-off 10-90ms Specification 13.6*8.6*5.2
Highlight

single channel loop detector

,

dual channel loop detector

,

vehicle presence pulse detector

Leave a Message
Product Description

Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 0

Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection

JUTAI single and dual channel loop detectors are professional-grade solutions engineered for accurate vehicle presence sensing and pulse detection, ideal for access control, gate automation, and traffic management scenarios. With industrial-grade build quality and flexible configuration, these detectors seamlessly adapt to indoor/outdoor installations while supporting seamless integration with gate controllers, traffic counters, and access systems.
Our product lineup covers two core series to meet diverse needs:
  • Single Channel (LD100 AC / LD102 DC): Specialized for basic vehicle presence detection and pulse-triggered actions, perfect for simple gate and industrial door automation.
  • Dual Channel (LD200 AC / LD202 DC): Equipped with advanced directional sensing and traffic counting capabilities, designed for entry/exit management, toll plazas, and dual-zone monitoring.
All detectors ensure reliable identification of cars, trucks, motorcycles, forklifts, and other vehicles, delivering consistent performance in harsh environmental conditions.

Key Features (Presence & Pulse Detection Optimization)

  • Adjustable Sensitivity for Precision: Single Channel models offer 16-level sensitivity tuning; Dual Channel variants provide 8-level independent adjustment per channel, effectively minimizing false triggers and adapting to vehicles of all sizes.
  • Multi-Mode Operation: Supports presence monitoring (continuous vehicle tracking), pulse output (one-time trigger actions), and auto-reset functions (all models); Dual Channel detectors add 3 configurable direction detection modes for traffic flow analysis.
  • Real-Time Status & Fault Alerts: LED indicators clearly display power, detection status, and loop faults (short/open circuit), enabling rapid troubleshooting and reducing operational downtime.
  • Industrial-Grade Durability: Weatherproof housing, wide operating temperature range (-40°C to +70°C), and 95% non-condensing humidity tolerance ensure stability in outdoor parking lots, industrial workshops, and high-traffic areas.
  • Hassle-Free Integration & Setup: Manual reset button confirms configuration changes instantly; compatible with standard automation equipment, no complex programming required for deployment.
  • Anti-Interference Design: 4-step selectable frequency (20–80 kHz for Single Channel; 20–100 kHz for Dual Channel) eliminates cross-talk with adjacent loops or electronic devices in dense environments.

Technical Specifications Summary

Parameter Single Channel (LD100 / LD102) Dual Channel (LD200 / LD202)
Power Supply 100–240V AC or 12–24V DC 100–240V AC or 12–24V DC
Detection Channels 1 2 Independent Channels
Sensitivity Adjustment 16-level 8-level per channel
Frequency Selection 4-step (20–80 kHz) 4-step (20–100 kHz)
Relay Outputs 2 (Presence + Pulse/Fault) 2 (One per channel: COM + NO)
Direction Detection Not Available Yes (Configurable via DIP switches)
Response Time 10–90 ms 10–90 ms
Operating Temperature -40°C to +70°C -40°C to +70°C
Indicators Power LED + Detection LED Power LED + CH1/CH2 Detection LEDs
Humidity Tolerance Up to 95% RH (non-condensing) Up to 95% RH (non-condensing)

Loop Installation Guide (Presence/Pulse Detection Optimization)

Loop Perimeter Recommended Wire Turns
3–4 meters 6 turns
4–6 meters 5 turns
6–10 meters 4 turns
10–20 meters 3 turns
Over 20 meters 2 turns

Ideal Applications (Presence & Pulse Detection Focus)

  • Single Channel Use Cases: Automatic barrier gate operation, industrial roller door activation, warehouse forklift entry sensing, security boom gate automation, basic vehicle presence signaling for access points.
  • Dual Channel Use Cases: Parking lot entry/exit counting systems, traffic flow monitoring & directional analysis, toll booth vehicle classification, dual-lane access control, loading dock management, industrial traffic coordination.

Why Choose JUTAI Loop Detectors for Presence & Pulse Detection?

  • 15+ years of specialized experience in vehicle detection technology, with a focus on presence and pulse detection reliability.
  • Comprehensive product range from basic single-channel solutions to advanced dual-channel systems for complex scenarios.
  • Strict quality control and full pre-shipment testing to ensure long-term performance in high-demand environments.
  • Support for OEM/ODM customization and standard orders, tailored to specific project requirements.
  • All products backed by a 2-year warranty and dedicated technical support for seamless deployment.

Selecting the Right Model

  • Choose Single Channel detectors for straightforward vehicle presence sensing and pulse-triggered automation (e.g., gate opening/closing).
  • Choose Dual Channel detectors for directional judgment, traffic counting, or dual-zone presence/pulse detection (e.g., entry/exit management).

Order Now – Enhance Your Vehicle Presence & Pulse Detection Performance

Contact us today to discuss your specific presence/pulse detection needs, request free samples, or get a competitive quotation for bulk orders. JUTAI’s single and dual channel loop detectors are designed to deliver precise, reliable performance for your access control, gate automation, and traffic management projects.

Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 1

Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 2

Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 3


Connections


Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 4




Indicators and Switches:

  • Power LED (RED): Illuminates to indicate "Power ON."
  • CH1 Detection LED:
    • Steady On: Indicates vehicle detection.
    • Slow Blinking: Indicates a loop short circuit or insufficient twists after the loop.
    • Fast Blinking: Indicates a loop open circuit or excessive twists after the loop.
  • CH2 Detection LED:
    • Steady On: Indicates vehicle detection.
    • Slow Blinking: Indicates a loop short circuit or insufficient twists after the loop.
    • Fast Blinking: Indicates a loop open circuit or excessive twists after the loop.

Sensitivity Selection:

  • Sensitivity and frequency adjustment is facilitated through a 7-way dip switch and 10-way dip switch settings.
  • Users can choose from 8 different sensitivity settings by configuring the dip switch positions according to the provided tables.
  • Dip switches 6, 7, and 8 govern CH1 sensitivity, ranging from 0.8 (least sensitive) to 0.015 (most sensitive).
  • Dip switches 3, 4, and 5 control CH2 sensitivity, ranging from 0.8 (least sensitive) to 0.015 (most sensitive).


Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 5




3. Switch 1=S1 : Channel 1 Loop Function Selection (10 way dip switch)


(1)(Switch 1) DIP 1 & DIP 2 Special Sensitivity Increase For Both Trailer (Both Channels).


Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 6


(2)(Switch 1=S1) D3, D4, D5 and (Switch 2=S2) D1, D2 Setting Special Functions (Mode1, 2, 3 Direction Detection. Mode 4, 5, 6 Normal mode, two loop detection are separated)


Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 7



(3)(Switch 1=S1) D6 & D7 & D8 and (Switch 2=S2) D3 & D4 & D5 Setting CH1 and CH2 Sensitivity Selection (Eight Levels Choices).


Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 8


(4)(Switch 1=S1) D9 & D10 and (Switch2=S2) D6, D7 Setting Frequency (20 K to 100 KHz).


Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 9
* Reset Button : Please note : The LD-200 must be reset every time a setting change is made to the Dip switches.

 

Installation Precautions and Troubleshooting:

  1. Coil Cutting Size and Embedding Guidelines are as shown in the diagram on the right.
  2. It is recommended to use ferromagnetic wires for the induction coil, with a total length of up to 500 meters.
  3. The cutting size of the coil should be a rectangle with a length of 1.0 to 2.0 meters and a width of 0.8 to 1.2 meters, avoiding right angles at corners as much as possible.
  4. Recommended installation overview of basic typical coil turns:
Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 10


When installation, please keep the product plug and socket in the vertical direction


Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 11


Application


The JUTAI LD200/202 double-channel vehicle loop detector series, equipped with direction recognition function, is ideal for numerous single-channel entry and exit scenarios. When integrated with the JUTAI One door controller (Model: AC-11), JUTAI gate barrier (Model: BR-110), and JUTAI long-range RFID reader (Model: PUHF-9), along with high-temperature resistance loop coils (Model: JTHT-11), it forms a seamless solution for single-channel entry/exit access control systems.


Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 12

The working principle is as follows:

  1. Entry Process:

    • When a car enters the community or parking lot, the two loop coils are pressed simultaneously.
    • The JUTAI Double Channel Loop Detector (LD-200/202) triggers the UHF reader located at the entrance.
    • The UHF reader reads the card ID and sends it to the controller (AC-11) via Wiegand output.
    • The controller verifies the ID's validity and outputs a relay signal to open the gate barrier.
    • The car enters the community or parking lot, and as it passes the barrier gate, the barrier arm lowers automatically.
    • The JUTAI Single Channel Loop Detector (LD-100/102) ensures safety and anti-smashing functionality during this process.
  2. Exit Process:

    • When a car exits the community or parking lot, it passes by an inside UHF reader.
    • The LD-200/LD-202 triggers the UHF reader, which reads the card and sends the ID to the controller.
    • The controller verifies the ID's validity and outputs a relay signal to open the gate barrier for the car to exit.
    • As the car passes through the barrier gate, the barrier arm lowers automatically.
    • The LD-100/102 provides safety and anti-smashing functionality during this process.
  3. Direction Recognition:

    • The Direction Recognition Function of LD-200/LD-202 ensures that the double channels loop detector does not trigger the signal again when the car passes another UHF reader, thereby recording only the entry or exit records in the system.
Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 13



The JUTAI LD-200/202 Double Channel Loop Detector can also function as two independent single-channel loop detectors. This configuration is suitable for standard one-in and one-out parking lots, where there is one barrier and one long-range reader at both the entrance and exit.

In this setup, one loop coil is used to trigger the reader and read the card, while the other loop coil is dedicated to the barrier's anti-smashing function. By utilizing the LD-200/202 as two independent loop detectors, there is a potential cost-saving benefit from an economic standpoint. This setup reduces some of the hardware costs associated with using separate detectors for each function.

This functionality is achieved by enabling the Independent Working Mode feature of the LD-200/202, allowing it to operate effectively in this dual capacity.


Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 14


Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 15Loop Detector Single And Dual Channel Models For Vehicle Presence Pulse Detection 16