Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function

Place of Origin China
Brand Name JUTAI
Certification CE
Model Number LD-202
Document LD-200.202.pdf
Minimum Order Quantity 1
Price Negotiation
Packaging Details Carton
Delivery Time 5 - 8 working days
Payment Terms T/T,L/C,D/A,D/P,Western Union,Paypal,,MoneyGram,Alipay
Supply Ability 1000 pieces per month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Power Requirements 12-24V Self-Turning Range 20-2000uh
Sensitivity 16-Way Selectable/ Highest 0.010%Dl/L/Lowest 2.56% Operation Temp -40 ~ +70℃
Response Times Turn-on 10-90ms/Turn-off 10-90ms Specification 13.6*8.6*5.2
Highlight

single channel loop detector

,

two channel loop detector

,

loop detector with direction detection

Leave a Message
Product Description

Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 0

Vehicle Loop Detector: Single Channel And Two Channel With Direction Detection Function

JUTAI vehicle loop detectors (single & two-channel variants) are professional-grade solutions engineered with optional direction detection, tailored for traffic management, access control, and entry/exit systems. Built with industrial durability and flexible configuration, they support precise vehicle presence sensing, pulse triggering, and (for two-channel models) directional judgment—seamlessly adapting to indoor/outdoor installations and integrating with gate controllers, traffic counters, and security systems.
Our product lineup meets diverse application needs:
  • Single Channel (LD100 AC / LD102 DC): Focused on reliable presence and pulse detection for basic automation (e.g., gate activation, industrial door control) without direction sensing.
  • Two Channel (LD200 AC / LD202 DC): Equipped with 3 configurable direction detection modes, ideal for entry/exit management, traffic counting, and bidirectional flow monitoring.
All detectors ensure consistent identification of cars, trucks, motorcycles, forklifts, and heavy-duty vehicles, maintaining stability in harsh environmental conditions.

Key Features (Direction Detection & Core Advantages)

  • Direction Sensing (Two Channel Exclusive): 3 configurable modes accurately identify vehicle travel direction (e.g., CH1→CH2 / CH2→CH1), enabling bidirectional traffic counting and entry/exit logic control.
  • Adjustable Sensitivity: Single Channel (16-level tuning); Two Channel (8-level independent adjustment per channel) – minimizes false triggers and adapts to vehicles of all sizes, including trailers.
  • Multi-Mode Operation: Supports presence monitoring (continuous vehicle tracking), pulse output (one-time triggers), and auto-reset (all models); Two Channel adds directional sensing for advanced traffic management.
  • Industrial-Grade Reliability: Weatherproof/dustproof housing, -40°C~+70°C operating temperature range, and 95% non-condensing humidity tolerance – resistant to industrial vibration, dust, and extreme weather.
  • Real-Time Status & Fault Alerts: LED indicators display power, detection status, and loop faults (short/open circuit), enabling rapid on-site troubleshooting to reduce downtime.
  • Anti-Interference Design: 4-step selectable frequency (20–80 kHz for Single Channel; 20–100 kHz for Two Channel) eliminates cross-talk with adjacent loops or electronic equipment.
  • Easy Integration: Manual reset button for configuration confirmation; dual relay outputs (per channel for Two Channel) connect seamlessly with standard automation and access control systems.

Technical Specifications Summary

Parameter Single Channel (LD100 / LD102) Two Channel (LD200 / LD202)
Power Supply 100–240V AC or 12–24V DC 100–240V AC or 12–24V DC
Detection Channels 1 2 Independent Channels
Direction Detection Not Available Yes (3 modes, DIP switch configurable)
Sensitivity Adjustment 16-level 8-level per channel
Frequency Selection 4-step (20–80 kHz) 4-step (20–100 kHz)
Relay Outputs 2 (Presence + Pulse/Fault) 2 (One per channel: COM + NO)
Response Time 10–90 ms 10–90 ms
Operating Temperature -40°C to +70°C -40°C to +70°C
Indicators Power LED + Detection LED Power LED + CH1/CH2 Detection LEDs
Humidity Tolerance Up to 95% RH (non-condensing) Up to 95% RH (non-condensing)
Loop Inductance Range 20–2000 µH 20–2000 µH per channel

Loop Installation Guide (Direction Detection Optimization)

Loop Perimeter Recommended Wire Turns
3–4 meters 6 turns
4–6 meters 5 turns
6–10 meters 4 turns
10–20 meters 3 turns
Over 20 meters 2 turns
Installation Note For direction detection (Two Channel), install loops 1m apart along the travel path; seal with quick-set epoxy or hot bitumen for road/industrial floor durability.

Ideal Applications (Direction Detection & Core Use Cases)

  • Single Channel Use Cases: Industrial door activation, parking gate automation, warehouse forklift detection, security boom gate control, basic access point presence sensing.
  • Two Channel Use Cases: Parking entry/exit counting systems, traffic flow direction analysis, toll booth vehicle classification, bidirectional access control, industrial entry/exit management, loading dock dual-lane monitoring.

Why Choose JUTAI Vehicle Loop Detectors?

  • 15+ years of specialized experience in vehicle detection technology, with direction sensing optimized for real-world traffic scenarios.
  • Comprehensive product range: from basic single-channel solutions to advanced two-channel detectors with direction detection.
  • Rigorous pre-shipment testing ensures reliability in high-demand industrial, commercial, and municipal environments.
  • OEM/ODM customization support + standard order flexibility, tailored to specific project requirements.
  • 2-year warranty + dedicated technical support for seamless integration and long-term performance.

Selecting the Right Model

  • Choose Single Channel for basic presence/pulse detection needs (e.g., simple gate/door automation).
  • Choose Two Channel for direction detection, bidirectional traffic counting, or dual-zone monitoring (e.g., entry/exit systems).

Order Now – Elevate Traffic & Access Control Precision

Contact us today to request samples, get customized quotes, or consult technical details. JUTAI’s loop detectors (single & two-channel with direction detection) deliver precise, durable performance for your traffic management and access control projects.

Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 1

Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 2

Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 3


Connections


Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 4




Indicators and Switches:

  • Power LED (RED): Illuminates to indicate "Power ON."
  • CH1 Detection LED:
    • Steady On: Indicates vehicle detection.
    • Slow Blinking: Indicates a loop short circuit or insufficient twists after the loop.
    • Fast Blinking: Indicates a loop open circuit or excessive twists after the loop.
  • CH2 Detection LED:
    • Steady On: Indicates vehicle detection.
    • Slow Blinking: Indicates a loop short circuit or insufficient twists after the loop.
    • Fast Blinking: Indicates a loop open circuit or excessive twists after the loop.

Sensitivity Selection:

  • Sensitivity and frequency adjustment is facilitated through a 7-way dip switch and 10-way dip switch settings.
  • Users can choose from 8 different sensitivity settings by configuring the dip switch positions according to the provided tables.
  • Dip switches 6, 7, and 8 govern CH1 sensitivity, ranging from 0.8 (least sensitive) to 0.015 (most sensitive).
  • Dip switches 3, 4, and 5 control CH2 sensitivity, ranging from 0.8 (least sensitive) to 0.015 (most sensitive).


Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 5




3. Switch 1=S1 : Channel 1 Loop Function Selection (10 way dip switch)


(1)(Switch 1) DIP 1 & DIP 2 Special Sensitivity Increase For Both Trailer (Both Channels).


Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 6


(2)(Switch 1=S1) D3, D4, D5 and (Switch 2=S2) D1, D2 Setting Special Functions (Mode1, 2, 3 Direction Detection. Mode 4, 5, 6 Normal mode, two loop detection are separated)


Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 7



(3)(Switch 1=S1) D6 & D7 & D8 and (Switch 2=S2) D3 & D4 & D5 Setting CH1 and CH2 Sensitivity Selection (Eight Levels Choices).


Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 8


(4)(Switch 1=S1) D9 & D10 and (Switch2=S2) D6, D7 Setting Frequency (20 K to 100 KHz).


Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 9
* Reset Button : Please note : The LD-200 must be reset every time a setting change is made to the Dip switches.

 

Installation Precautions and Troubleshooting:

  1. Coil Cutting Size and Embedding Guidelines are as shown in the diagram on the right.
  2. It is recommended to use ferromagnetic wires for the induction coil, with a total length of up to 500 meters.
  3. The cutting size of the coil should be a rectangle with a length of 1.0 to 2.0 meters and a width of 0.8 to 1.2 meters, avoiding right angles at corners as much as possible.
  4. Recommended installation overview of basic typical coil turns:
Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 10


When installation, please keep the product plug and socket in the vertical direction


Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 11


Application


The JUTAI LD200/202 double-channel vehicle loop detector series, equipped with direction recognition function, is ideal for numerous single-channel entry and exit scenarios. When integrated with the JUTAI One door controller (Model: AC-11), JUTAI gate barrier (Model: BR-110), and JUTAI long-range RFID reader (Model: PUHF-9), along with high-temperature resistance loop coils (Model: JTHT-11), it forms a seamless solution for single-channel entry/exit access control systems.


Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 12

The working principle is as follows:

  1. Entry Process:

    • When a car enters the community or parking lot, the two loop coils are pressed simultaneously.
    • The JUTAI Double Channel Loop Detector (LD-200/202) triggers the UHF reader located at the entrance.
    • The UHF reader reads the card ID and sends it to the controller (AC-11) via Wiegand output.
    • The controller verifies the ID's validity and outputs a relay signal to open the gate barrier.
    • The car enters the community or parking lot, and as it passes the barrier gate, the barrier arm lowers automatically.
    • The JUTAI Single Channel Loop Detector (LD-100/102) ensures safety and anti-smashing functionality during this process.
  2. Exit Process:

    • When a car exits the community or parking lot, it passes by an inside UHF reader.
    • The LD-200/LD-202 triggers the UHF reader, which reads the card and sends the ID to the controller.
    • The controller verifies the ID's validity and outputs a relay signal to open the gate barrier for the car to exit.
    • As the car passes through the barrier gate, the barrier arm lowers automatically.
    • The LD-100/102 provides safety and anti-smashing functionality during this process.
  3. Direction Recognition:

    • The Direction Recognition Function of LD-200/LD-202 ensures that the double channels loop detector does not trigger the signal again when the car passes another UHF reader, thereby recording only the entry or exit records in the system.
Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 13



The JUTAI LD-200/202 Double Channel Loop Detector can also function as two independent single-channel loop detectors. This configuration is suitable for standard one-in and one-out parking lots, where there is one barrier and one long-range reader at both the entrance and exit.

In this setup, one loop coil is used to trigger the reader and read the card, while the other loop coil is dedicated to the barrier's anti-smashing function. By utilizing the LD-200/202 as two independent loop detectors, there is a potential cost-saving benefit from an economic standpoint. This setup reduces some of the hardware costs associated with using separate detectors for each function.

This functionality is achieved by enabling the Independent Working Mode feature of the LD-200/202, allowing it to operate effectively in this dual capacity.


Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 14


Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 15Vehicle Loop Detector Single Channel And Two Channel With Direction Detection Function 16